HI3149B Refillable Combination ORP Electrode with BNC Connector

$479.00

The HI3149B is a glass body, refillable, open junction ORP electrode with a BNC connector. This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS™) technology, and a platinum sensing ring. Compatible with all electrode filling solutions, this electrode is specifically designed for non-aqueous titrations.

 

Description

The HI3149B is a glass body, refillable, open junction ORP electrode with a BNC connector. This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS™) technology, and a platinum sensing ring. Compatible with all electrode filling solutions, this electrode is specifically designed for non-aqueous titrations.

The HI3149B uses a platinum pin, glass body, double ceramic junction and is refillable with 3.5M KCl 

 

Platinum Sensing Pin

The HI3149 ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

Double Junction

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

Refillable

The HI3149B is a refillable probe. Since it is a single junction ORP electrode the fill solution is the HI7082 3.5M KCl. If using a refillable ORP electrode, the fill cap should be removed prior to measurement. Removing the cap creates positive head pressure in the reference cell allowing for a higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.

BNC Connector

The HI3149B uses a BNC connector. This type of connector is universal in that it can be used on any pH/mV meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Additional information

Weight 0.11 kg
Parameter

ORP

Specifications

SKU HI3149B
Name HI3149B ORP electrode
Measurement Range ORP: ±2000 mV
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate CPS™
Refill Electrolyte KCl 3.5M
Body Material glass
Tip / Shape platinum pin
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range -5 to 60°C
(23 to 140°F)
Body Length/Overall Length 150 mm / 205.5 mm
Temperature Sensor no
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use non-aqueous titrations