Hanna Instruments Canada
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: (800) 842-6629
Hanna Instruments Canada
Customer Support: (800) 842-6629

Nickel High Range Portable Photometer - HI96726

The HI96726 is no longer available.

Below is the link to a new meter that has been upgraded with many advanced features including an improved optical system, dot matrix LCD that offers a graphical tutorial mode to help the user through the measurement process and is waterproof including the cuvette assembly.

Both meters use the same reagents.

view new meter

Description

The HI96726 portable photometer is for the high range measurement of nickel. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

*Reagents ordered separately

cal check standards

CAL Check™ standards with certificate

The HI96726-11 CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check™ function.

Supplied with Certificate of Analysis

  • Lot number
  • Expiration date
  • Standard value @ 25℃
  • Reference meter NIST traceable

Provided storage containers

  • Light tight
  • Protects from accidental breakage

Additional information

Weight 0.08 kg
Parameter

Nickel

Specifications

SKU HI96726-web
Name Nickel High Range Portable Photometer – HI96726
Nickel Range 0.00 to 7.00 g/L nickel
Nickel Resolution 0.01 g/L
Nickel Accuracy ±0.07 mg/L ±4% of reading
Nickel Method adaptation of the photometric method
Photometer/Colorimeter Light Source tungsten lamp
Photometer/Colorimeter Light Detector silicon photocell with narrow band interference filter @ 575 nm
Battery Type/Life 9V battery
Automatic Shut-Off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 360g (12.7oz.)
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)

Ordering Info

HI96726 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.

Manuals

Nickel High Range Portable Photometer – HI96726