Hanna Instruments Canada
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: (800) 842-6629
Hanna Instruments Canada
Customer Support: (800) 842-6629

HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-No-Logging probe - no turbidity-20m (65.6')

$5,217.00

In stock

The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.

Description

Meter with or without GPS

*select option at checkout

GPS

Built in GPS Receiver

  • 12 channel GPS receiver and antenna
  • Tracks location using satellites to within 30 feet
  • Latitude and longitude recorded with readings
  • Location naming for GPS coordinates
  • Distance from current location to stored location
  • Hi929829 software supplied integrates data collected with Google™ maps
    • Measurement readings including GPS coordinates
    • Date and time
    • Named locations and remarks
    • Sample number

Google™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™.

Two probes to choose from (Basic or Logging)

*select option at checkout

The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default the HI9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.

HI7609829 Basic Probe

  • Digital probe that is less than 2 inches in diameter
  • 3 color-coded sensor inputs
  • IP68 rating for continuous immersion in water
  • Multistrand –mulitconductor cable rated for 150 lbs (intermittent use)
  • Available with 4, 10, or 20 meter cable
  • Weighted shield protects all sensors

HI7609829 probe without logging

HI7629829 Autonomously Logging Probe

  • Same as basic probe but with logging capability
  • Logs data independent of HI9829 meter
  • Operates on 4 “AA” batteries for up to 70 days*
  • Stores up to 140, 000 single parameter readings or 35, 000 for all parameters
  • Logs data from 1 second to 3 hours
  • Choose to be supplied with EC or EC/Turbidity sensor
  • Supplied with USB cable for direct connection to Window’s compatible PC

*All channels logging at 10 minute intervals with no averaging

HI7629829 logging probe

Color Coded, Field Replaceable Sensors

HI9829 multiparameter pH meter HI9829 multiparameter pH meter (in carrying case)

Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.

Backlit Dot Matrix LCD Display – The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.

Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.

Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

Auto-sensor Recognition – The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.

Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.

Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.

Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.

GLP Data – HI9829 includes a GLP feature thatallows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.

Data Logging – The HI9829 allows users to store up to 44, 000 continuous or log-on-demand samples with logging intervals from one second to three hours.

Graphing Capability – Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.

PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI7698291 USB adapter and HI929829 software.

Long Battery Life – The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C ” NiMH rechargeable batteries that provide up to 140 hours of battery life*

Rugged thermoformed carrying case – The HI9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.

* Without GPS or turbidity measurements

On-screen Features

GPS option

GPS Option
The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.

calibration

Quick Calibration
The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.

graphing

Graphing Capability
Trend graphing with sample date and time may be viewed on the display or transferred to PC.

fast tracker

Fast Tracker™—Tag Identification System

HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.

iButton. Tags are Easy to Install

Install the optional TAGs near your sampling points for quick and easy iButton. readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.

Additional information

Weight 6.67 kg
Parameter

Ammonium, Chloride, Conductivity/TDS, Dissolved, Nitrate, ORP, Oxygen, pH, Resistivity, Salinity, Turbidity

pH Accuracy

±0.02 pH

pH Calibration

10.01) or one custom buffer, 6.86, 7.01, 9.18, automatic one, or three points with automatic recognition of five standard buffers (pH 4.01, two

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

EC Accuracy

±1% of reading or ±1 µS/cm whichever is greater

EC Calibration

111.8 mS/cm) or custom point, 12.88 mS/cm, 1413 µS/cm, 5.00 mS/cm, 80.0 mS/cm, automatic single point, with six standard solutions (84 µS/cm

EC Range

0 to 200 mS/cm (absolute EC up to 400 mS/cm)

EC Resolution

Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10., Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm

TDS Accuracy

±1% of reading or ±1 ppm (mg/L), whichever is greater

TDS Calibration

based on conductivity or salinity calibration

TDS Range

0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)

TDS Resolution

Automatic ppt (g/L): 0.001 ppt, Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Range

-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K

Specifications

SKU HI9829-02201
Name HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-No-Logging probe – no turbidity-20m (65.6′)
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range ±2000 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
mV Range ±600.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.5 mV
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.
EC Accuracy ±1% of reading or ±1 µS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Resolution Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt
TDS Accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration based on conductivity or salinity calibration
Salinity (PSU) Range 0.00 to 70.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity (PSU) Calibration based on conductivity calibration
Salinity (Seawater Sigma) Range 0.0 to 50.0 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Resolution 0.1 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Accuracy ±1 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Calibration based on conductivity or salinity calibration
Resistivity Range 0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm
Resistivity Resolution dependent on resistivity reading
Resistivity Calibration based on conductivity calibration
Dissolved Oxygen Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved Oxygen Resolution 0.1%; 0.01 ppm (mg/L)
Dissolved Oxygen Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3
Dissolved Oxygen Calibration automatic one or two points at 0 and 100% or one custom point
Turbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNU
Turbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
Turbidity Accuracy ±0.3 FNU or ±2 % of reading, whichever is greater
Turbidity Calibration Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
Temperature Resolution 0.01 K, 0.01 °C, 0.01 °F
Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration automatic at one custom point
Temperature Compensation automatic from -5 to 55 °C (23 to 131 °F)
Ammonium Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Ammonium Accuracy ±5 % reading or 2 ppm
Ammonium Calibration 1 or 2 point, 10 ppm and 100 ppm
Chloride Range 0.6 to 200.0 ppm Cl (as Cl- )
Chloride Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Chloride Accuracy ±5 % of reading or 2 ppm
Chloride Calibration 1 or 2 point, 10 ppm and 100 ppm
Nitrate Range 0.62 to 200.0 ppm Ni (as NO3 – -N)
Nitrate Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
Nitrate Calibration 1 or 2 point, 10 ppm and 100 ppm
Logging Memory 44,000 records (continuous logging or log-on-demand of all parameters)
Logging Interval one second to three hours
Connectivity USB (with HI 929829 software)
Battery Type/Life 1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
Weight 750 g (26.5 oz.)
GPS 12 channel receiver 10 m (30 ft) accuracy

Ordering Info

The HI9829 and HI98290 (GPS model) are supplied with a HI710140 hard carrying case, HI7612VDC adapter, HI7698292 probe maintenance kit, HI929829 PC application software, HI7698291 USB cable (PC to meter), HI710045 power supply cable, HI710046 cigarette lighter power cable, HI9829-25 quick calibration solution, HI920005 iButton with holder (5), HI7609829-1 pH/ORP sensor, HI7609829-2 galvanic DO sensor, HI7609829-3 EC sensor, HI7698290 short calibration beaker, HI7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual. *CALibration beaker and HI7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI9829-16 0 FNU, HI769829-17 20 FNU, and HI9829-18 200 FNU.

Manuals

HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-No-Logging probe – no turbidity-20m (65.6′)