Hanna Instruments Canada
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: (800) 842-6629
Hanna Instruments Canada
Customer Support: (800) 842-6629

HI2000 Series Digital Process ORP Probes-Gold-PTFE-25m (82.0')

$998.00

In stock

The HI2000 series of digital ORP probes are industrial sensors used for monitoring and control applications. These probes are available with a choice of ceramic or PTFE reference junction and platinum or gold sensor material. All probes have a built-in pt100 temperature sensor and have a chemically resistant PVDF body that has ¾” NPT threads on the front end for insertion mounting.

These probes are compatible with the HI510 Universal Process Controller.

  • Available with either platinum or gold sensor.
  • Choice standard ceramic junction or chemically resistant PTFE junction.
  • Digital probe that is automatically detected and transmits data by RS485 connection.

Description

A Worldwide Leader in Electrode Manufacturing

Since the beginning of the 1990’s Hanna has been a leader in the research & development of ORP electrode technology. The HI2000 series of digital ORP probes represent the continual evolution of the technology. The HI2000 series perform all measurements within the probe and then transfer the data digitally to a process meter with a digital probe input.

The use of digital sensors allows for a process meter to be updated measuring a different parameter without changing controllers. This technology allows for a facility that has multiple control points to only have to maintain a single version of a controller.

The other advantage is that the digital transmission of measurement data is immune to electrical noise generated by motors, pumps, and humid environments. The digital signal can be transmitted over very long distances. The HI2000 series of digital probes are available with cable lengths up to 50 meters.

All Hanna industrial digital ORP electrodes are combination type, i.e. the reference half cell and the measurement half cell are assembled in the same body. All of the probes are made with a chemically resistant PVDF body and have a pt100 temperature sensor.

matching pin

Each ORP electrode is provided with an internal matching pin that helps to avoid typical problems caused by grounding loop current, such as:

  • progressive damage of the electrode
  • fluctuating measurements
  • poor process regulation

In many industrial applications there is a potential for a ground loop. This can happen when the ground of the process line is different than the ground of a controller/transmitter.

When a traditional electrode/controller system is used, the electrode reference is connected from the electrode to the instrument and current can flow through the reference half cell, causing fluctuations in reading and serious damage to the Ag/AgCl element. The potential matching pin shields the reference from external electrical fields. Shown above, the matching pin allows the measurement to stabilize and ensures effective process regulation. In order to function properly, the matching pin has to be continuously immersed in the measured solution and for this reason is placed near the electrode junction.

ORP dimensions

Installation

These electrodes have been designed with ¾” external thread for easy installation for in-line applications. HANNA instruments® also provides a series of probe holders for submersion tank installations.

Front thread ¾” NPT

  • Direct in-line installation ¾” standard tee
  • Immersion installation in vessel, tank, plating bath with HI 60501 (PVC) or HI 60503 (PVDF) electrode holders with adjustable immersion level: min 10 cm, max 70 cm
  • Direct pipe installation with HI 60542 PVC electrode holder, 2″ thread

HI2000 Series Digital ORP Electrode FEATURES/BENEFITS:

Junction

Two junction types are available:

  • Annular non-clogging PTFE junction, for testing solutions with high content of suspended solids, aggressive chemicals, or for high pressure installation
  • Ceramic junction that is ideal for drinking water and other low conductivity applications.

Sensor Material

HI2000 series is available with two types of sensing material.

  • Sensors with a platinum band. The platinum material is preferred due to the ability to fuse with a glass support. Platinum is commonly used in oxidations reactions and for baths used for disinfection.
  • Sensors with a gold band. The gold material is commonly used with reduction reactions.

Temperature Sensor

  • All HI2000 series of digital ORP probes have a built-in 3-wire Pt100 sensor for temperature measurements.

Connection Type

  • Electrodes are wired for direct connection to the HI510 Universal Process Controller.

Cable Length

  • HI2000 digital ORP probes are available with a 5, 10, 15, 25, or 50 m of cable.

PVDF Body

  • The PVDF body used for the Flat Tip Series withstands high pressure and high temperature applications, and guarantees a high chemical and mechanical resistance. These characteristics make the PVDF material the most recommended for many industrial applications.

Additional information

Weight 0.91 kg
Parameter

ORP, Temperature

Specifications

SKU HI2004-2825
Name HI2000 Series Digital Process ORP Probes-Gold-PTFE-25m (82.0′)
Description digital ORP probe with built-in pt100 temperature sensor
Measurement Range ±2000 mV
Junction Type/Flow Rate doouble junction
Type of Electrolyte polymer
Body Material PVDF
Environment -5 to 100 ºC (23 to 212 ºF)
Matching Pin yes
Max. Pressure 6 bar (87 psi)
Body Length/Overall Length 140 mm
Temperature Sensor pt100
Outer Diameter 22.5 mm
Output Signal digital RS485
Connector Type direct wire connection
Probe Mounting 3/4 in. NPT threaded connection for in-line mounting or submersion mounting with probe holder

Manuals

HI2000 Series Digital Process ORP Probes-Gold-PTFE-25m (82.0′)