Hanna Instruments Canada
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: (800) 842-6629
Hanna Instruments Canada
Customer Support: (800) 842-6629

Gel Filled PEI Body pH Electrode with Quick Connect DIN Connector - HI12303

$163.00

In stock

The HI12303 is a Polyetherimide (PEI) body, double junction pH electrode with a built-in temperature sensor and connects to the meter that has a Quick Connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190.

The HI12303 pH electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with low temperature glass and is protected by the fins of the durable PEI body. This design consideration excels in measurements with portable meters due to the durability and that the probe does not require maintenance other than cleaning and calibration.

  • Chemically-Resistant PEI Body
  • Double Junction Reference
  • Low Temperature (LT) Glass

Description

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI12303 uses Low Temperture (LT) glass, spherical bulb, polyetherimide (PEI) body, single ceramic frit, and double junction.

digital electrode

spherical-tip

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

pei-body

PEI Electrode Body

The PEI (polyetherimide) electrode body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many harsh chemicals.

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

din connector

Quick Connect Din Connector

The HI12303 uses a Quick Connect DIN connector that makes attaching and removing the probe simple and easy. This type of connector is proprietary to the meter. See specifications table for compatible meters.

Single Junction Versus Double Junction pH Electrodes

single vs double junction electrodes

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.

Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate that can form to clog the junction.

Additional information

Weight 0.34 kg
Parameter

pH

Specifications

SKU HI12303
Name Gel Filled PEI Body pH Electrode with Quick Connect DIN Connector – HI12303
Measurement Range pH: 0 to 13
Reference Cell Type double, Ag/AgCl
Junction Type/Flow Rate ceramic, single / 15-20 µL/h
Type of Electrolyte gel
Body Material PEI
Tip / Shape spheric (dia: 7.5 mm)
Matching Pin no
Max. Pressure 2 bar
Temperature Operating Range 0 to 70°C (32 to 158°F) – LT
Body Length/Overall Length 120 mm / 163.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 5-pole; 1 m (3.3 in.)
Connector Type quick connect DIN
Amplifier yes
Recommended Use field applications

Manuals

Gel Filled PEI Body pH Electrode with Quick Connect DIN Connector – HI12303