Hanna Instruments Canada
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: (800) 842-6629
Hanna Instruments Canada
Customer Support: (800) 842-6629

Automatic Potentiometric (pH/mV/ISE) Titration System - HI902C-Single probe input

$9,095.00

SKU: HI902C1-01 Categories , ,

In stock

The HI902C is an automatic titrator that complements our wide range of products dedicated to efficient and accurate laboratory analysis. The HI902C potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations. This powerful titrator automatically dispenses the titrant, detects the endpoint, and performs all necessary calculations and graphing. In addition to titration, the HI902C also operates as a fully functional pH, mV/ORP, and ion selective electrode (ISE) meter.

Description

Titrator Capabilities

HI902C Angled

Enhanced Security Options

Administrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.

Dynamic Titrant Dosing

The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.

Signal Stability Timing

The signal stability feature monitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.

Equivalence Endpoint Detection

Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.

Multiple Equivalence Point Detection

The HI902C can detect multiple equivalence points during one titration as specified and required in certain standard methods and applications.

Method Sequencing

The HI902C offers users the option of linking two methods. This allows for two analyses to be run on the same sample including direct measurements, single endpoint titrations, multiple equivalence point titrations, and back titrations.

Multiple Titration Types

Paired with the right electrode from our sensor line, our potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations.

Direct Measurement Functionality

The HI902C performs as a high accuracy pH, ORP, and ion selective meter that can link, log, and report direct measurements. Users can easily track and manage data without the hassle of manual record keeping.

Burettes & Dosing System

Exchangeable Burette System

With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.

Multiple Burette Sizes

The HI902C comes standard with a 25 mL burette but may be equipped with a 5 mL, 10 mL, or 50 mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.

Precision Dosing Pump

Our unmatched 40, 000 step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.

Chemically Resistant Tubing

Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.

Automatic Reagent Addition

A second burette may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition.

Burettes and Dosing

Interface & Display

Screenshots

Interactive Color Display

A large, color LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values.

Detailed Titration Graphs

A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.

Simple & Quick Navigation

Virtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.

Data & Storage

Customizable Analysis Reports

Each analysis report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application.

Flexible GLP Management

All necessary GLP (Good Laboratory Practice) information can be recorded with each sample including: sample identification, company and operator name, date, time, electrode ID codes, and calibration information.

Effortless Data Transfer

Data can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The conveniently located port allows for the transfer of titration methods, titration reports, and software upgrades via USB flash drive.

USB Storage

Connectivity & Functionality

HI902C Angled

Autosampler Connectivity

The HI902C works seamlessly with our HI921 Autosampler featuring 16 or 18 sample tray options, automatic tray identification, and automatic beaker detection. Up to three peristaltic pumps for reagent addition and removal can be connected and real-time analysis and sequencing progress is visible on the HI902C display as well as indicated by the LED lights of the Autosampler.

Multifunctional

HI902C functions as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.

Multiple Connections

The titrator offers device support for two analog boards, allowing up to two electrodes, two burettes, and two stirrers to be connected to one unit simultaneously.

Multiple Peripherals

Users can print reports directly from the titrator using a parallel port interface. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.

Methods of Analysis

Customizable Methods

The HI902C can store up to 100 user-defined or standard titration and direct measurement methods. Each method may be modified and optimized for performance based on application and user requirements.

Titration Method Support

Onsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support for any questions you might have along the way.

Market Specific Methods Packs

Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more. Ask our Sales Consultants about our library of market specific titration methods.

Adaptable Standard Methods

Our technical experts can program and optimize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI902C system.

Electrodes

Additional information

Weight 11.43 kg
Parameter

Acidity, Alkalinity, Magnesium, Nickel, Nitrogen, ORP, pH, Reducing Sugars, Salinity, Sulfur Dioxide, Tartaric Acid, Titratable Acidity, Titration

pH Accuracy

±0.001 pH

pH Calibration

eight standard buffers and five custom buffers, Up to five-point calibration

pH Range

-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH

pH Resolution

0.1; 0.01; 0.001 pH

Temperature Accuracy

±0.1°C; ±0.2°F; ±0.1K, excluding probe error

Temperature Range

-5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K

Specifications

SKU HI902C1-01
Name Automatic Potentiometric (pH/mV/ISE) Titration System – HI902C-Single probe input
mV Range -2000.0 to 2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.1 mV
mV Calibration single-point offset
pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
pH Resolution 0.1; 0.01; 0.001 pH
pH Accuracy ±0.001 pH
pH Calibration up to five-point calibration, eight standard buffers and five custom buffers
pH Temperature Compensation manual (MTC) or automatic (ATC)
ISE Range 1 10⁻⁶ to 9.99 10¹⁰
ISE Resolution 1; 0.1; 0.01
ISE Accuracy ±0.5% monovalent; ±1% divalent
ISE Calibration up to five-point calibration, seven standard solutions and five user-defined standards
Temperature Range -5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K
Temperature Resolution 0.1°C; 0.1°F; 0.1K
Temperature Accuracy ±0.1°C; ±0.2°F; ±0.1K, excluding probe error
Potentiometric Titrations acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometri
Measurement Units user-specified expression of concentration units to suit specific calculation requirements
Endpoint Criteria equivalence point (1st or 2nd derivative) or fixed pH/mV value
Flow Rate user-selectable from 0.1 mL/min to 2 x burette volume/min
Dosing Accuracy ±0.1% of full burette volume
Burette Size Capability 5, 10, 25, and 50 mL
Dosing Pump Resolution 1/40000
Stirrer Type propeller type
Stirrer Speed 100 to 2500 rpm
Stirrer Resolution resolution 100 rpm
Titrator Methods up to 100 methods (standard and user-defined)
Reports up to 100 titration and pH/mV/ISE reports
Real Time & Stored Graphs mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode: pH/mV/concentration versus time
GLP Conformity instrumentation data storage and printing capabilities
Connectivity flash drive compatibility for transfer of methods and reports
Peripheral Devices connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232, interface for autosample
Display 5.7 in. (320 x 240 pixel) backlit color LCD
Keypad polycarbonae
Languages English, Portuguese, Spanish
Power Supply 100-240 VAC US plug (type A)
Environment operating: 10 to 40°C (50 to 104°F), up to 95% RH storage: -20 to 70°C (-4 to 158°F), up to 95% RH
Dimensions 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)
Weight approximately 9 kg (20 lbs.)

Ordering Info

HI902C1 titrator is supplied with one analog board, overhead propeller stirrer with stand, 25 mL glass burette, dosing pump drive, temperature sensor, USB cable, 256 Mb USB flash drive and PC software.

Manuals

Automatic Potentiometric (pH/mV/ISE) Titration System – HI902C-Single probe input